import os
import sys
import time
import signal
import logging
from gconf import gconf
from syncdutils import update_file, select, waitpid
class Monitor(object):
def __init__(self):
self.state = None
def set_state(self, state):
if state == self.state:
return
self.state = state
logging.info('new state: %s' % state)
if getattr(gconf, 'state_file', None):
update_file(gconf.state_file, lambda f: f.write(state + '\n'))
def monitor(self):
def sigcont_handler(*a):
"""
Re-init logging and send group kill signal
"""
md = gconf.log_metadata
logging.shutdown()
lcls = logging.getLoggerClass()
lcls.setup(label=md.get('saved_label'), **md)
pid = os.getpid()
os.kill(-pid, signal.SIGUSR1)
signal.signal(signal.SIGUSR1, lambda *a: ())
signal.signal(signal.SIGCONT, sigcont_handler)
argv = sys.argv[:]
for o in ('-N', '--no-daemon', '--monitor'):
while o in argv:
argv.remove(o)
argv.extend(('-N', '-p', ''))
argv.insert(0, os.path.basename(sys.executable))
self.set_state('starting...')
ret = 0
def nwait(p, o=0):
p2, r = waitpid(p, o)
if not p2:
return
return r
def exit_signalled(s):
""" child teminated due to receipt of SIGUSR1 """
return (os.WIFSIGNALED(s) and (os.WTERMSIG(s) == signal.SIGUSR1))
def exit_status(s):
if os.WIFEXITED(s):
return os.WEXITSTATUS(s)
return 1
conn_timeout = int(gconf.connection_timeout)
while ret in (0, 1):
logging.info('-' * conn_timeout)
logging.info('starting gsyncd worker')
pr, pw = os.pipe()
cpid = os.fork()
if cpid == 0:
os.close(pr)
os.execv(sys.executable, argv + ['--feedback-fd', str(pw)])
os.close(pw)
t0 = time.time()
so = select((pr,), (), (), conn_timeout)[0]
os.close(pr)
if so:
ret = nwait(cpid, os.WNOHANG)
if ret != None:
logging.debug("worker died before establishing connection")
else:
logging.debug("worker seems to be connected (?? racy check)")
while time.time() < t0 + conn_timeout:
ret = nwait(cpid, os.WNOHANG)
if ret != None:
logging.debug("worker died in startup phase")
break
time.sleep(1)
else:
logging.debug("worker not confirmed in %d sec, aborting it" % \
conn_timeout)
os.kill(cpid, signal.SIGKILL)
ret = nwait(cpid)
if ret == None:
self.set_state('OK')
ret = nwait(cpid)
if exit_signalled(ret):
ret = 0
else:
ret = exit_status(ret)
if ret in (0,1):
self.set_state('faulty')
time.sleep(10)
self.set_state('inconsistent')
return ret
def monitor():