summaryrefslogtreecommitdiffstats
path: root/xlators/protocol/server/src/server-common.c
diff options
context:
space:
mode:
authorAmar Tumballi <amarts@redhat.com>2017-07-19 23:08:05 +0530
committerAmar Tumballi <amarts@redhat.com>2017-08-04 05:26:42 +0000
commit590ae48c65a60c93c2e5407e3f663cef3daacc55 (patch)
tree82e948d6e48900878a9977aceef3535506d05207 /xlators/protocol/server/src/server-common.c
parentf68887999e89d894c3125e3b26517221ad1543fc (diff)
glusterfsd: allow subdir mount
Changes: 1. Take subdir mount option in client (mount.gluster / glusterfsd) 2. Pass the subdir mount to server-handshake (from client-handshake) 3. Handle subdir-mount dir's lookup in server-first-lookup and handle all fops resolution accordingly with proper gfid of subdir 4. Change the auth/addr module to handle the multiple subdir entries in option, and valid parsing. How to use the feature: `# mount -t glusterfs $hostname:/$volname/$subdir /$mount_point` Or `# mount -t glusterfs $hostname:/$volname -osubdir_mount=$subdir /$mount_point` Option can be set like: `# gluster volume set <volname> auth.allow "/subdir1(192.168.1.*),/(192.168.10.*),/subdir2(192.168.8.*)"` Updates #175 Change-Id: I7ea57f76ddbe6c3862cfe02e13f89e8a39719e11 Signed-off-by: Amar Tumballi <amarts@redhat.com> Reviewed-on: https://review.gluster.org/17141 Smoke: Gluster Build System <jenkins@build.gluster.org> Reviewed-by: Shyamsundar Ranganathan <srangana@redhat.com> CentOS-regression: Gluster Build System <jenkins@build.gluster.org>
Diffstat (limited to 'xlators/protocol/server/src/server-common.c')
-rw-r--r--xlators/protocol/server/src/server-common.c68
1 files changed, 55 insertions, 13 deletions
diff --git a/xlators/protocol/server/src/server-common.c b/xlators/protocol/server/src/server-common.c
index 1dc3a9cf9bd..b972918f37f 100644
--- a/xlators/protocol/server/src/server-common.c
+++ b/xlators/protocol/server/src/server-common.c
@@ -10,8 +10,24 @@
#include "xdr-nfs3.h"
void
-server_post_stat (gfs3_stat_rsp *rsp, struct iatt *stbuf)
+server_post_stat (server_state_t *state, gfs3_stat_rsp *rsp, struct iatt *stbuf)
{
+ if (state->client->subdir_mount) {
+ if (gf_uuid_compare (stbuf->ia_gfid,
+ state->client->subdir_gfid)) {
+ /* This is very important as when we send iatt of
+ root-inode, fuse/client expect the gfid to be 1,
+ along with inode number. As for subdirectory mount,
+ we use inode table which is shared by everyone, but
+ make sure we send fops only from subdir and below,
+ we have to alter inode gfid and send it to client */
+ uuid_t gfid = {0,};
+
+ gfid[15] = 1;
+ stbuf->ia_ino = 1;
+ gf_uuid_copy (stbuf->ia_gfid, gfid);
+ }
+ }
gf_stat_from_iatt (&rsp->stat, stbuf);
}
@@ -166,8 +182,25 @@ server_post_ftruncate (gfs3_ftruncate_rsp *rsp, struct iatt *prebuf,
}
void
-server_post_fstat (gfs3_fstat_rsp *rsp, struct iatt *stbuf)
+server_post_fstat (server_state_t *state, gfs3_fstat_rsp *rsp,
+ struct iatt *stbuf)
{
+ if (state->client->subdir_mount) {
+ if (gf_uuid_compare (stbuf->ia_gfid,
+ state->client->subdir_gfid)) {
+ /* This is very important as when we send iatt of
+ root-inode, fuse/client expect the gfid to be 1,
+ along with inode number. As for subdirectory mount,
+ we use inode table which is shared by everyone, but
+ make sure we send fops only from subdir and below,
+ we have to alter inode gfid and send it to client */
+ uuid_t gfid = {0,};
+
+ gfid[15] = 1;
+ stbuf->ia_ino = 1;
+ gf_uuid_copy (stbuf->ia_gfid, gfid);
+ }
+ }
gf_stat_from_iatt (&rsp->stat, stbuf);
}
@@ -444,17 +477,6 @@ server_post_lookup (gfs3_lookup_rsp *rsp, call_frame_t *frame,
root_inode = frame->root->client->bound_xl->itable->root;
- if (inode == root_inode) {
- /* we just looked up root ("/") */
- stbuf->ia_ino = 1;
- rootgfid[15] = 1;
- gf_uuid_copy (stbuf->ia_gfid, rootgfid);
- if (inode->ia_type == 0)
- inode->ia_type = stbuf->ia_type;
- }
-
- gf_stat_from_iatt (&rsp->stat, stbuf);
-
if (!__is_root_gfid (inode->gfid)) {
link_inode = inode_link (inode, state->loc.parent,
state->loc.name, stbuf);
@@ -463,6 +485,26 @@ server_post_lookup (gfs3_lookup_rsp *rsp, call_frame_t *frame,
inode_unref (link_inode);
}
}
+
+ if ((inode == root_inode) ||
+ (state->client->subdir_mount &&
+ (inode == state->client->subdir_inode))) {
+ /* we just looked up root ("/") OR
+ subdir mount directory, which is root ('/') in client */
+ /* This is very important as when we send iatt of
+ root-inode, fuse/client expect the gfid to be 1,
+ along with inode number. As for subdirectory mount,
+ we use inode table which is shared by everyone, but
+ make sure we send fops only from subdir and below,
+ we have to alter inode gfid and send it to client */
+ stbuf->ia_ino = 1;
+ rootgfid[15] = 1;
+ gf_uuid_copy (stbuf->ia_gfid, rootgfid);
+ if (inode->ia_type == 0)
+ inode->ia_type = stbuf->ia_type;
+ }
+
+ gf_stat_from_iatt (&rsp->stat, stbuf);
}
void