parent | 541e6a0079e50aa36e37270a91d86fccb2467ee4 (diff) |
glusterd: Don't spawn new glusterfsds on node reboot with brick-mux
With brick multiplexing enabled, upon a node reboot new bricks were
not being attached to the first spawned brick process even though
there wasn't any compatibility issues.
The reason for this is that upon glusterd restart after a node
reboot, since brick services aren't running, glusterd starts the
bricks in a "no-wait" mode. So after a brick process is spawned for
the first brick, there isn't enough time for the corresponding pid
file to get populated with a value before the compatibilty check is
made for the next brick.
This commit solves this by iteratively waiting for the pidfile to be
populated in the brick compatibility comparison stage before checking
if the brick process is alive.
> Reviewed-on: https://review.gluster.org/17307
> Reviewed-by: Atin Mukherjee <amukherj@redhat.com>
> Smoke: Gluster Build System <jenkins@build.gluster.org>
> NetBSD-regression: NetBSD Build System <jenkins@build.gluster.org>
> CentOS-regression: Gluster Build System <jenkins@build.gluster.org>
(cherry picked from commit 13e7b3b354a252ad4065f7b2f0f805c40a3c5d18)
Change-Id: Ibd1f8e54c63e4bb04162143c9d70f09918a44aa4
BUG: 1453087
Signed-off-by: Samikshan Bairagya <samikshan@gmail.com>
Reviewed-on: https://review.gluster.org/17352
Smoke: Gluster Build System <jenkins@build.gluster.org>
NetBSD-regression: NetBSD Build System <jenkins@build.gluster.org>
CentOS-regression: Gluster Build System <jenkins@build.gluster.org>
Reviewed-by: Atin Mukherjee <amukherj@redhat.com>
Reviewed-by: Raghavendra Talur <rtalur@redhat.com>
Diffstat (limited to 'cli')
0 files changed, 0 insertions, 0 deletions