From 2ade36cd98ea0f5bd2a8f619a19c20438318afaf Mon Sep 17 00:00:00 2001 From: Amar Tumballi Date: Mon, 23 Oct 2017 21:17:52 +0200 Subject: protocol/server: fix the comparision logic in case of subdir mount without the fix, the stat entry on a file would return inode==1 for many files, in case of subdir mount This happened with the confusion of return value of 'gf_uuid_compare()', it is more like strcmp, instead of a gf_boolean return value, and hence resulted in the bug. Change-Id: I31b8cbd95eaa3af5ff916a969458e8e4020c86bb BUG: 1505527 Signed-off-by: Amar Tumballi --- xlators/protocol/server/src/server-common.c | 60 ++++++++++++++--------------- 1 file changed, 30 insertions(+), 30 deletions(-) diff --git a/xlators/protocol/server/src/server-common.c b/xlators/protocol/server/src/server-common.c index b972918f37f..ce3308937ca 100644 --- a/xlators/protocol/server/src/server-common.c +++ b/xlators/protocol/server/src/server-common.c @@ -12,22 +12,22 @@ void server_post_stat (server_state_t *state, gfs3_stat_rsp *rsp, struct iatt *stbuf) { - if (state->client->subdir_mount) { - if (gf_uuid_compare (stbuf->ia_gfid, - state->client->subdir_gfid)) { - /* This is very important as when we send iatt of - root-inode, fuse/client expect the gfid to be 1, - along with inode number. As for subdirectory mount, - we use inode table which is shared by everyone, but - make sure we send fops only from subdir and below, - we have to alter inode gfid and send it to client */ - uuid_t gfid = {0,}; - - gfid[15] = 1; - stbuf->ia_ino = 1; - gf_uuid_copy (stbuf->ia_gfid, gfid); - } + if (state->client->subdir_mount && + !gf_uuid_compare (stbuf->ia_gfid, + state->client->subdir_gfid)) { + /* This is very important as when we send iatt of + root-inode, fuse/client expect the gfid to be 1, + along with inode number. As for subdirectory mount, + we use inode table which is shared by everyone, but + make sure we send fops only from subdir and below, + we have to alter inode gfid and send it to client */ + uuid_t gfid = {0,}; + + gfid[15] = 1; + stbuf->ia_ino = 1; + gf_uuid_copy (stbuf->ia_gfid, gfid); } + gf_stat_from_iatt (&rsp->stat, stbuf); } @@ -185,22 +185,22 @@ void server_post_fstat (server_state_t *state, gfs3_fstat_rsp *rsp, struct iatt *stbuf) { - if (state->client->subdir_mount) { - if (gf_uuid_compare (stbuf->ia_gfid, - state->client->subdir_gfid)) { - /* This is very important as when we send iatt of - root-inode, fuse/client expect the gfid to be 1, - along with inode number. As for subdirectory mount, - we use inode table which is shared by everyone, but - make sure we send fops only from subdir and below, - we have to alter inode gfid and send it to client */ - uuid_t gfid = {0,}; - - gfid[15] = 1; - stbuf->ia_ino = 1; - gf_uuid_copy (stbuf->ia_gfid, gfid); - } + if (state->client->subdir_mount && + !gf_uuid_compare (stbuf->ia_gfid, + state->client->subdir_gfid)) { + /* This is very important as when we send iatt of + root-inode, fuse/client expect the gfid to be 1, + along with inode number. As for subdirectory mount, + we use inode table which is shared by everyone, but + make sure we send fops only from subdir and below, + we have to alter inode gfid and send it to client */ + uuid_t gfid = {0,}; + + gfid[15] = 1; + stbuf->ia_ino = 1; + gf_uuid_copy (stbuf->ia_gfid, gfid); } + gf_stat_from_iatt (&rsp->stat, stbuf); } -- cgit