summaryrefslogtreecommitdiffstats
path: root/xlators/mgmt/glusterd/src/glusterd-volgen.c
diff options
context:
space:
mode:
authorRavishankar N <ravishankar@redhat.com>2018-02-14 12:15:53 +0530
committerAtin Mukherjee <amukherj@redhat.com>2018-03-07 04:48:09 +0000
commitbd2c45fe3180fe36b042d5eabd348b6eaeb8d3e2 (patch)
tree654acff37c5ff9f38b03f3e8b4e9e3e2c5c357c9 /xlators/mgmt/glusterd/src/glusterd-volgen.c
parent685d4409f9405a527c87b41d1d89f798729d30f4 (diff)
glusterd: volume get fixes for client-io-threads & quorum-type
1. If a replica volume created on glusterfs-3.8 was upgraded to glusterfs-3.12, `gluster vol get volname client-io-threads` displayed 'on' even though it wasn't and the xlator wasn't loaded on the client-graph. This was due to removing certain checks in glusterd_get_default_val_for_volopt as a part of commit 47604fad4c2a3951077e41e0c007ceb979bb2c24. Fix it. 2. Also, as a part of op-version bump-up, client-io-threads was being loaded on the clients during volfile regeneration. Prevent it. 3. AFR assumes quorum-type to be auto in newly created replic 3 (odd replica in general) volumes but `gluster vol get quorum-type` displays 'none'. Fix it. Change-Id: I19e586361ed1065c70fb378533d3b4dac1095df9 BUG: 1545056 Signed-off-by: Ravishankar N <ravishankar@redhat.com>
Diffstat (limited to 'xlators/mgmt/glusterd/src/glusterd-volgen.c')
-rw-r--r--xlators/mgmt/glusterd/src/glusterd-volgen.c10
1 files changed, 8 insertions, 2 deletions
diff --git a/xlators/mgmt/glusterd/src/glusterd-volgen.c b/xlators/mgmt/glusterd/src/glusterd-volgen.c
index f9fcf88a256..caf421165f8 100644
--- a/xlators/mgmt/glusterd/src/glusterd-volgen.c
+++ b/xlators/mgmt/glusterd/src/glusterd-volgen.c
@@ -59,7 +59,6 @@ extern struct volopt_map_entry glusterd_volopt_map[];
} \
} while (0 /* CONSTCOND */)
-
static int
volgen_graph_build_clients (volgen_graph_t *graph, glusterd_volinfo_t *volinfo,
dict_t *set_dict, void *param);
@@ -524,6 +523,11 @@ volgen_graph_set_options_generic (volgen_graph_t *graph, dict_t *dict,
odt.data_t_fake = _gf_false;
data = dict_get (dict, vme->key);
+ if (!strcmp (vme->key, "performance.client-io-threads") &&
+ dict_get_str_boolean (dict, "skip-CLIOT",
+ _gf_false) == _gf_true) {
+ continue;
+ }
if (data)
process_option (vme->key, data, &odt);
@@ -6672,11 +6676,13 @@ glusterd_create_volfiles (glusterd_volinfo_t *volinfo)
"Could not generate client volfiles");
- ret = glusterd_generate_gfproxyd_volfile (volinfo);
+ ret = glusterd_generate_gfproxyd_volfile (volinfo);
if (ret)
gf_log (this->name, GF_LOG_ERROR,
"Could not generate gfproxy volfiles");
+ dict_del (volinfo->dict, "skip-CLIOT");
+
out:
return ret;
}